A interesting question was posed to me recently and I though many others would benefit from the answer.
The question was:
“Hi Adrian,
I hope you had a good Christmas. Best wishes to you and Brenda for care-free travel in the New Year.
I had a thought: (dangerous as that might be) If you put an ozone recirc loop on your storage tank, could you go further and loop it back to the entry point (of city water) prior to the filters, RO, etc. and then run it through the entire system from beginning to end?
Regards,
PG”
The answer is that ozone is in fact sometimes applied before an RO, as is UV, to kill microbiological activity. Ozone has the same effect on an RO as chlorine, it damages the membranes. Ozone must be applied to the inlet water at a concentration adequate to provide complete sterilization and must be in contact with the inlet water, for at least 4 minutes for appropriate contact time. A simple loop would not be adequate. A full ozone mixing system would be required. This would involve an air drier, ozone generator large enough for the dosage in this application. An ozone mixing tank will also be required, in order for the ozone to be in contact for the required 4 minutes and a pump to circulate the mixing tank to achieve total ozone contact. The ozone injection would also need to be monitored so as to not achieve more than the required dosage of ozone, as excess ozone needs to be monitored in the room used for safety of personnel.
To remove ozone you need to use carbon filtration or destroy the ozone with UV. To destroy ozone with UV you need to spec the UV to be able to handle 10 times the flow rate that would be required for normal UV sterilization. Let’s say your max flow rate is, full system fast flush of 6gpm on the RO. The UV must be spec’d for 60gpm. This makes it a bit expensive for removal.
UV is an easier way to go prior to RO, as you do not have to remove it as with ozone. UV can be applied prior to the RO or post in the outlet line of the RO. I typically prefer pre RO as any bacteria, moulds, algae can grow through the membrane and perhaps lead to membrane issues as the membrane media can be plugged.
Anecdotally, I learned of one company that applied ozone prior to RO expecting reduced bacteria levels. In fact the exact opposite was the result. The bacterial count post ozone injection and prior to RO spiked many fold the original count. This result is contrary to what would be normally expected. You need to consider that in certain situations, all the killed bacteria with broken cells walls, ozone rips through he cell membrane which results in cell death. The dead and damaged bacteria remain in the water stream. This dead bacteria now is a readily available food source for any remaining live bacteria. You have just provided a veritable buffet for the live bacteria left, to feed on and the resulting bacteria count exploded. Often this explosion can be in a matter of hours or days.
I always caution people that ozone has a place in water sterilization but it will not and does not solve all sterilization problems satisfactorily and there can be negative results on occasion.